CAREFUSION Alaris PC 8015 IV Infusion Pump

This Infusion pump provides a common user interface for monitoring modules and programming the various infusion, which aids in reducing the complexity at the point of care. It is intended for pediatric, adult, and neonatal care in the healthcare facility and hospital. It helps optimize patient care and infusion therapy by using the Guardrails software to measure IV formula data. The color display clearly communicates critical programming, monitoring, infusion, and hospital defined policy information.

Category:

This Infusion pump provides a common user interface for monitoring modules and programming the various infusion, which aids in reducing the complexity at the point of care. It is intended for pediatric, adult, and neonatal care in the healthcare facility and hospital. It helps optimize patient care and infusion therapy by using the Guardrails software to measure IV formula data. The color display clearly communicates critical programming, monitoring, infusion, and hospital defined policy information.

The Alaris 8015 PC Unit is the core of the Alaris System and provides a common user interface for programming infusion and monitoring modules. This helps to reduce complexity at the point of care. Using the Alaris Systems manager you can wirelessly upload the latest drug and IV parameters, clinical advisories and important safety enhancements. This helps to ensure that nurses and other care givers have the most up to date information.

PCU Battery:

The PC Unit 8015 from Alaris is equipped with a 12 volt, 4000 mAH nickel-metal hydride battery. The battery is charging whenever the instrument is plugged into an AC receptacle. The life expectancy of the battery is dependent on the amount of use, the depth of discharge, and the state of the charge that is maintained. Generally, the battery has the longest life if the instrument is plugged in and battery use is infrequent.

Memory:

  • The System configuration/data set is stored in compact flash memory along with operating software.
  • The events and error logs are stored in the onboard flash memory in the Alaris PC unit and modules. This is a nonvolatile memory and can be held indefinitely or until replaced with new data and not lost when power is turned off or the battery is in a weak/discharged state.
  • Module-specific parameters are stored for 8 hours when the system is turned off. After 8 hours of continuous off-time, or if a module is detached, module-specific trend data (if applicable) and module-specific operating parameters are automatically purged. If a PCA, SpO2 or EtCO2 module is detached and replaced with another PCA, SpO2, or EtCO2 module, its module-specific trend data is purged.

Main Characteristics:

  • Wireless connectivity
  • Powerful analytics
  • Exceptional versatility
  • Increased protection for IV safety
Features Specifications
Height 8.8 inches
Width 6.9 inches
Depth 9 inches
Weight 7.2 lbs
Graphical Trends 20 min, 1, 2, 4, 6, 8, 10, 12 and 24h
Numerical Trends All parameters, sampled every 5 min and after NIBP measurement
Alarms Adjustable high and low limit alarms
Recorder Thermal array, 3-channels, paper width 50 mm
Screen Display size and type 10.4 inch LCD active matrix color Number of traces Up to 6. Display resolution 640 x 480 pixels

 

Scroll to Top